INDUSTRIAL REGRIGERATION

A2L solutions

INTRODUCTION

Designed to fulfil the needs of industrial processes

Our aim is to add technological value to our clients’ refrigeration projects, so as to facilitate installation and enhance reliability guarantees.

As A2L refrigerants are non-toxic and slightly flammable, they are often used to reduce global warming potential (GWP) even further compared with other gases, to create a more environmentally friendly installation. For installers seeking a cost-effective option maintaining a conventional system design, our A2L-based chillers represent an outstanding choice. Our tried and tested design and the integration of robust and efficient elements give these chillers a long useful life with low running costs.

The condensers are integrated into the chiller. If condensation is performed by water, we may suggest multi-tubular or plate heat exchangers. If air condensation is required, the condensation batteries and fans are integrated into the ceiling of the exterior module intended for outdoor installation. We are often asked to incorporate full heat recovery in air-cooled chillers. In such cases, we install a PHE at the outlet of each circuit.

TECHNICAL SPECIFICATIONS

General characteristics

01.

Pumping paddles

Possibility of integrating pumping sets to transfer the cold liquid from the evaporator or the hot liquid from the PHE heat recoverer (as an option).

02.

Flexibility

Our technical team have more than 20 years of experience in the design and manufacture of technically complex equipment, offering the flexibility to adapt our solutions to the specific needs of each project, and so offer the best solution. Please contact our technical office to request a price quotation for a chiller to meet your specific needs.

ADVANTAGES

Key benefits

2L refrigerant designed to reduce environmental impact. R1234ZE is an HFO with zero ODP and a GWP below 1, making this a balanced choice of refrigerant for both clients and the environment.
Plug-and-Play solution to reduce installation costs: use of our chiller will reduce the refrigerant tube array in the installation.
Low refrigerant load compact form to optimise space and reduce the refrigerant load.
Simple maintenance with limited risks. Electronic fans with regulators providing automatic speed regulation.

INFORMATION

Technical information

RFU/+7 BISHRC

Cooling capacity
91kW – 828kW

Shaft power
25.48kW – 221.1kW

EER
3.57 – 3.74

RFU/+7 STRP

Cooling capacity
102kW – 878.1kW

Shaft power
32.6kW – 289.5kW

EER
3.03 – 3.13

RFU/-8 BISHRC

Cooling capacity
53.4kW – 801kW

Shaft power
22.7kW – 357.6kW

EER
2.08 – 2.35

RFU/-8 STRP

Cooling capacity
49.2kW – 877.8kW

Shaft power
24.8kW – 434.4kW

EER
1.90 – 2.02

RELATED PROJECTS

Genuine results

Solutions applied to genuine challenges: we demonstrate how precision and adaptability transform each challenge into concrete results.